Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters

Database
Language
Document Type
Year range
1.
Perfusion ; 38(1 Supplement):159-160, 2023.
Article in English | EMBASE | ID: covidwho-20239477

ABSTRACT

Objectives: To evaluate the outcomes and risk factors associated with mortality of patients cannulated on ECMO in the context of covid infection during the pandemics in a newly implemented ECMO center Methods: This was a unicentric observational retrospective study performed at Real Hospital Portugues, in Recife, state of Pernambuco, Brazil. All consecutive patients with laboratory confirmed SARS-CoV-2 infection cannulated for VV-ECMO or VA-ECMO for severe ARDS from march 2020 to december 2021 were included retrospectively. Patients recieving ECMO for isolated refratory cardiogenic shock were excluded. Descriptive statistics and association tests were used to analyze characteristics, management and patient outcomes during that period. Result(s): In our cohort of 47 ECMO for covid associated ARDS (CARDS), 39 patients (83%) were admitted by our emergency department. 8 patients (17%) had been transferred from other hospitals as soons as they had been cannulated. 32 patients (68%) were male, median age was 50 years (18-69). Mean body mass index was 31 (21,4-46,3). 37 patients (78%) had at least 1 comorbidity. Major bleeding occurred in 34 (72%) patients. Venous thromboembolism and hemolysis ocurred in 19 (40%) and 13 (23%) patients, respectively. When we compared treatments before ECMO initiation (imunoglobulin, tocilizuman, nitric oxide, neuromuscular blockade and proning), proning was associated with better survival (RR 0,67 IC 0,46-0,97 p 0,029). The mean duration in mechanical ventilation until ECMO cannulation was 9,69 days and mean time in ECMO was 23 days. The 90- day mortality was approximately 72%. Conclusion(s): The only variable associated with a better chance of survival was proning before ECMO. Our mortality (72%) is higher than reported from a recent meta-analysis of 1986 ECMO patients implanted during the first pandemic year(37,1%). However it is similar to a German populational registry of covid patients receiving VV-ECMO (73%). Althought it;s impossible to make causal inferences with such a design and sample sizes, we believe that describing the experience of smaller and newly implemented ECMO centers serves as motivation to improve quality and also to plan for future episodes of pressure on health system.

2.
Genetics and Molecular Research ; 21(1), 2022.
Article in English | EMBASE | ID: covidwho-1969626

ABSTRACT

The SARS-CoV-2 pandemic has demonstrated the need for genomic epidemiology surveillance. To date, various methodologies have been applied, including metagenomic approaches and amplicon-based sequencing associated with high-throughput sequencing platforms. We adapted some details in amplicon-based sequencing using a SARS-CoV-2 community panel (Illumina AmpliSeq), with additional modifications for balanced and high-quality sequencing using the MiSeq platform. The modified protocol was used to detect circulating SARS-CoV-2 variants in Goiás state, Brazil. Initially, RNA samples were obtained from swab samples from 15 patients from the state of Goiás, Brazil, in November/2020 and February/2021 to validate protocol steps. The libraries were prepared following AmpliSeq for Illumina workflow with modifications;subsequently, we analyzed 305 positive samples collected from the state of Goiás from December 2020 to July 2021. For protocol improvement, we removed the need to treat samples with DNAse and demonstrated the importance of quantification by qPCR before and after library dilution. No fragmentation pattern was observed in the samples analyzed with Bioanalyzer. The libraries returned sequencing results that were used for genome assembly and variant detection. We were able to assemble SARS-CoV-2 genomes from 318 samples, which were used to identify 13 variants of coronavirus circulating in Goiás throughout those months. Variants of concern, such as Alpha (B.1.1.7), Gamma (P.1) and Delta (B.1.617.2) were detected;the latter was detected at first in Goiás in April 2021. The modifications in the workflow we developed were successfully applied to detect SARS-CoV-2 variants, resulting in high coverage genome assembly, and they can be used to increase the number of genome sequences and aid in epidemiological surveillance in Brazil.

SELECTION OF CITATIONS
SEARCH DETAIL